Climate Thermal Solutions
Creating a fresh air system within an enclosed space is easier said than done. The accumulation of heat within an enclosure threatens all electrical devices. We provide a range of cabinet thermal solutions to protect the electrical components within your data centers and production lines. Whether you need a thermoelectric cooler, a heat exchanger, a filter fan, or an air conditioner, Delta’s innovative solutions are engineered to maintain a set temperature within an enclosure. Industry-leading thermo management solutions guarantee a contaminant-free environment while protecting electronic components. Our catalog of thermal management products offers flexible production capabilities to enable bespoke solutions for single-piece and large-scale rollouts. Some of the advantages of our cabinet thermal systems include the following:
- Enhanced performance - Cost-effective solutions - Genuine temperature control - Smaller sizes - Mitigate overheating risk
Our extensive catalog of cabinet thermal products enables you to select the solutions that suit your setup, layout, and industry. Mixing and matching several solutions can enable you to reach the performance goals of your program. Contact our sales team to discuss the advantages of each cabinet thermal solution.
Estimate your required cooling capacity by clicking here :
Delta industrial air conditioners use active compressor-based cooling to keep internal enclosure temperatures below ambient. These slim air cons employ a variable speed DC inverter compressor and dual rotor design to achieve a high COP with reduced vibration and low operating noise. All Delta air conditioners feature Delta’s high quality DC brushless fans engineered to run continuously for a minimum of 80,000 hours, or nine years.
Hide
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
HEC1000AFR
1000 W / 3143 BTU
32.0H x 11.8W x 9.5D
810H x 299W x 240D
115 VAC
6.4
65
50.7 / 27.0
UL Recognized
Outdoor
HEC2010FFA
ACU 2000 / 6800 HEX 100WK
37.2H x 19.9W x 9.8D
945H x 505W x 250D
230VAC & 48VDC
16.5
65
88.0 / 40.0
UL Recognized, CE
Outdoor
HEC2500BFE
8000 W / 2500 BTU
43.0H x 15.7W x 10.9D
1093H x 400W x 276D
230 VAC
3.8 ~ 4.4
62
88.0 / 40.0
UL Recognized
Outdoor
HEC1000BFS
1000 W / 3143 BTU
32H x 11.8W x 9.5D
810H x 299W x 240D
230 VAC
2.4
65
50.7 / 27.0
UL Recognized
Outdoor
HEC1000BFR
1000 W / 3143 BTU
32H x 11.8W x 9.5D
810H x 299W x 240D
230 VAC
2.4
65
50.7 / 27.0
UL Recognized
Outdoor
HEC0700BFB
700 W / 2380 BTU
21.5H x 12.4W x 6.9D
545H x 315W x 175D
230 VAC
1.3
60
35.3 / 16.0
UL Recognized, CE
Outdoor
HEC0600BFS
600 W / 2049 BTU
20H x 10W x 10D
508H x 254W x 254D
230 VAC
1.6
63
35.3 / 16.0
UL Recognized
Outdoor
HEC0600BFR
600 W / 2049 BTU
20H x 10W x 10D
508H x 254W x 254D
230 VAC
1.6
63
35.3 / 16.0
UL Recognized, CE
Outdoor
HEC0500BFA
500 W / 1870 BTU
21.7H x 11.6W x 6.3D
550H x 295W x 160D
230 VAC
4.1
61
35.3 / 16.0
UL Recognized, CE
Outdoor
HEC1000AFS
1000 W / 3143 BTU
32.0H x 11.8W x 9.5D
810H x 299W x 240D
115 VAC
6.4
65
50.7 / 27.0
UL Recognized
Outdoor
HEC0800PB
800 W / 2720 BTU
27.6H x 19.7W x 7.9D
700H x 500W x 200D
48
3.9
62
61.7 / 28.0
UL Recognized, CE
Outdoor
HEC0600AFS
600 W / 2049 BTU
20H x 10W x 10D
508H x 254W x 254D
115 VAC
4.3
60
34.2 / 15.5
UL Recognized
Outdoor
HEC0600AFR
600 W / 2049 BTU
20H x 10W x 10D
508H x 254W x 254D
115 VAC
4.3
60
34.2 / 15.5
UL Recognized
Outdoor
HEC2000XA
2000 W / 6800 BTU
29.4H x 17.6W x 7.9D
746H x 446W x 200D
48
13.8
62
81.6 / 37.0
CE
Outdoor
HEC1000PC
1000W / 3400 BTU
27.6H x 19.7W x 7.9D
700H x 500W x 200D
48
5.6
62
61.7 / 28.0
CE, cURus, TUV
Outdoor
HEC0800PC
800W / 2720 BTU
31.3H x 15.0W x 6.4D
796H x 383W x 163D
48VDC
3.8
52
59.5 / 27.0
CE, cURus, TUV
Outdoor
HEC1500PB
1500W / 5100 BTU
27.6H x 19.7W x 7.9D
700H x 500W x 200D
48
12.5
62
61.7 / 28.0
UL Recognized, CE
Outdoor
HEC1200PB
1200W / 4010 BTU
27.6H x 19.7W x 7.9D
700H x 500W x 200D
48
7.3
62
61.7 / 28.0
UL Recognized, CE
Outdoor
HEC1000PB
1000W / 3400 BTU
27.6H x 19.7W x 7.9D
700H x 500W x 200D
48
5.6
62
61.7 / 28.0
UL Recognized, CE
Outdoor
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
Part number (Download spec sheets)
Impeller Diameter (mm)
Voltage (VAC)
Max. Speed (RPM)
Min. Speed (RPM)
Protection/ Option
Ingress Protection
Certification
10
--
--
--
--
IP54
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP54
10
--
--
--
--
--
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP54
10
--
--
--
--
IP55
10
--
--
--
--
IP54
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
48 VDC
--
--
--
IP55
10
48 VDC
--
--
--
IP55
10
48 VDC
--
--
--
IP55
Delta air-to-air heat exchangers are a closed-loop system with advanced fan and core technology to bring internal enclosure temperatures to ambient. Delta heat exchangers feature Delta DC brushless fans engineered to run continuously for 80,000 hours, or nine years. Standard and custom designs are available.
Hide
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
HEX050QA
50 W/°C
6.1H x 21.7Wx 17.0D
155H x 550W x 434D
48
1.4
64
19.8 / 9.0
UL Recognized, CE
Outdoor
HEX080QA
80 W/°C
10.4H x 21.9W x 19.7D
265H x 555W x 500D
48
1.5
64
31.1 / 15.0
UL Recognized, CE
Outdoor
HEX010VA
10 W/°C
16.3H x 10.8W x 2.6D
415H x 275W x 65D
24
1.2
61
8.8 / 4.0
UL Recognized, CE
Outdoor
HEX020VA
20 W/°C
23.2H x 11.1W x 3.9D
590H x 283W x 99D
24
0.9
54
15.4 / 7.0
UL Recognized, CE
Outdoor
HEX050PA
45 W/°C
19.7H x 17.5W x 6.0D
500H x 445W x 152D
48
1.2
65
22.0 / 10.0
UL Recognized, CE
Outdoor
HEX015VA
15 W/K
23.2 x 5.9 x 3.1
510 H x 253 W x 78 D
24 VAC
1.2
65
11 / 5
UL Recognized, CE
Outdoor
HEX110QA
110 W
21.1 H x 17.6 W x 8.7 D
536 H x 447 W x 220 D
48 VAC
4
75
33.1 lbs / 15 kg
UL Recognized, CE
Outdoor
HEX070PB
70 W/K
37.0H x 19.3W x 3.9D
940H x 490W x 100D
48 VAC
3.8
65
38.5 / 17.5
UL Recognized, CE
Outdoor
HEX100PG
100 W/K
36H x 18W x 8.8D
917H x 457W x 223D
48 VAC
6
69
59.4 / 27.0
UL Recognized, CE
Outdoor
HEX180PB
180 W/K
29.1H x 17.3W x 9.8D
740H x 440W x 249D
48 VAC
6.4
67
55.0 lbs / 25.0 kg
UL Recognized, CE
Outdoor
HEX080PD
80 W/°C
37.4H x 17.7W x 5.9D
950H x 450W x 150D
48
2.2
65
41.9 / 19.0
UL Recognized, CE
Outdoor
HEX120PA
120 W/°C
45.3H x 18.5W x 7.6D
1151H x 471W x 193D
48 VDC
4.1
64
72.8 / 33.0
UL Recognized, CE
Outdoor
HEX160PA
160 W/°C
50.9H x 22.3W x 9.6D
1294H x 567W x 243D
48
3.1
65
88.2 / 40.0
UL Recognized, CE
Outdoor
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
Part number (Download spec sheets)
Impeller Diameter (mm)
Voltage (VAC)
Max. Speed (RPM)
Min. Speed (RPM)
Protection/ Option
Ingress Protection
Certification
10
48 VDC
--
--
--
IP55
10
48 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
Delta thermoelectric coolers provide slightly below ambient cooling in tight spaces. A TEC module is a sandwich of components (Peltier chips, heat sinks and fans) which provides cooling without the need for refrigerant or a compressor. All Delta TEC’s incorporate Delta DC brushless fans engineered to run continuously for 80,000 hours, or nine years. Standard and custom designs are available.
Hide
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
HET200PB
200 W
7.1H x 15.7W x 8.2D
180H x 400W x 208D
48
7.4
62
19.8 / 9.0
UL , CUL, TUV, CE
Outdoor
HET200PC-B
200 W
7.1H x 15.7W x 5.6D
181H x 400W x 143D
48
7.4
66
13.2 / 6.0
UL , CUL, TUV, CE
Outdoor
HET200VB
200 W
7.1H x 15.7W x 8.2D
180H x 400W x 208D
24
12.2
61
19.8 / 9.0
UL Recognized, CE
Outdoor
HET200VC
200 W
7.1H x 15.7W x 6.6D
181H x 400W x 169D
24
12
62
13.2 / 6.0
UL , CUL, TUV, CE
Outdoor
HET400PA
400 W
8.3H x 17.7W x 9.0D
210H x 450W x 228D
48 VDC
11.7
65
24.2 / 11.0
UL Recognized, CE
Outdoor
HET200VB-A01
200 W
7.1H x 15.7W x 8.2D
180H x 400W x 208D
24
12.2
61
19.8 / 9.0
UL Recognized, CE
Outdoor
HET200VC-A01
200 W
7.1H x 15.7W x 6.6D
181H x 400W x 169D
24
23
62
13.2 / 6.0
UL , CUL, TUV, CE
Outdoor
HET200PB-A01
200 W
7.1H x 15.7W x 8.2D
180H x 400W x 208D
48
7.4
62
19.8 / 9.0
UL , CUL, TUV, CE
Outdoor
HET400PA-A01
400 W
8.3H x 17.7W x 9.0D
210H x 450W x 228D
48 VDC
11.7
65
24.2 / 11.0
UL Recognized, CE
Outdoor
HET200PC
200 W
7.1H x 15.7W x 6.6D
181H x 400W x 169D
48
6.1
62
13.2 / 6.0
UL , CUL, TUV, CE
Outdoor
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
Part number (Download spec sheets)
Impeller Diameter (mm)
Voltage (VAC)
Max. Speed (RPM)
Min. Speed (RPM)
Protection/ Option
Ingress Protection
Certification
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
24 VDC
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
10
--
--
--
--
IP55
Cabinet heaters provide protection for enclosed electronics and equipment in low-temperature environments. Delta heaters have a Positive Temperature Coefficient (PTC) heating element for increased safety and reduced operating costs. PTC heaters generate only the heat necessary for the desired temperature, versus at a constant rate, saving energy while helping to prevent overheating and burnout. Standard and custom designs are available.
Hide
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
HEH030PA
300 W heating
5.9H x 5.7W x 1.8D
150H x 145W x 45D
48 VDC
7.5
N/A
1.3 / 0.5
CE, cURus, TUV
Indoor
HEH050PA
500 W heating
5.9H x 5.7W x 1.8D
150H x 145W x 45D
48VDC
12.5
N/A
1.3 / 0.6
UL Recognized, CE
Indoor
HEH070PA
700 W heating
5.9H x 5.7W x 1.8D
150H x 145W x 45D
48VDC
14.5
N/A
1.1 / 0.5
UL Recognized, CE
Indoor
HEH100PA
1000 W heating
9.4H x 7.3W x 2.2D
240H x 185W x 57D
48VDC
22.0
N/A
3.3 / 1.5
UL Recognized, CE
Indoor
HEH030BA
300 W heating
5.9H x 5.7W x 1.8D
150H x 145W x 45D
220VAC
1.5
N/A
1.1 / 0.5
UL Recognized, CE
Indoor
HEH050BA
500 W heating
5.9H x 5.7W x 1.8D
150H x 145W x 45D
220 VAC
2.5
N/A
1.1 / 0.5
UL Recognized, CE
Indoor
HEH070BA
700 W heating
5.9H x 5.7W x 1.8D
150H x 145W x 45D
220 VAC
4.5
N/A
1.1 / 0.5
UL Recognized, CE
Indoor
HEH095BA
950 W heating
6.6H x 5.7W x 2.3D
167H x 145W x 100D
220 VAC
4.5
54.0 (typ.) at 1M (sound pressure)
3.3 / 1.5
UL Recognized, CE
Indoor
HEH100BA
1000 W heating
9.3H x 7.3W x 2.3D
235H x 185W x 58D
220 VAC
5.0
N/A
3.3 / 1.5
UL Recognized, CE
Indoor
HEH150BA
1500 W heating
9.3H x 7.3W x 2.3D
235H x 185W x 58D
220 VAC
7.2
N/A
3.3 / 1.5
UL Recognized, CE
Indoor
HEH030BB
300 W heating
5.7H x 3.0W x 4.1D
145H x 75W x 105D
220 VAC
1.65
N/A
1.32 / 0.6
N/A
Indoor
HEH100PB
1000
1.7H X 19.0W x 7.0D
44H x 483W x 177D
48
22.0
N/A
5.0 / 2.3
UL Recognized, CE
Indoor
HEH080AB
800 W heating
7.4H x 4.3W x 3.1D
187H x 108W x 80D
115 VAC
7
N/A
1.8 / 0.8
UL Recognized
Indoor
HEH080BB
800 W heating
7.4H x 4.3W x 3.1D
187H x 108W x 80D
230 VAC
3.5
N/A
1.8 / 0.8
UL Recognized
Indoor
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
Part number (Download spec sheets)
Impeller Diameter (mm)
Voltage (VAC)
Max. Speed (RPM)
Min. Speed (RPM)
Protection/ Option
Ingress Protection
Certification
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
--
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
10
--
--
--
--
IP20 (IEC60529)
High CFM filter fans for dust sensitive industrial applications with easy maintenance.
Suggested Applications: Industrial Automation, Automotive Assembly, Package Handling Equipment, Food and Beverage Process Controls, and Wind Energy Systems.
Hide
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
HEF070AAA
12 W
8.03 x 8.03 x 4.21 inch
204 x 204 x 107mm
AC 115 V
0.17 A
46
1.94 lbs / 0.88 kg
UL Listed, CE
Outdoor
HEF070BAA
14 W
8.03 x 8.03 x 4.21 inch
204 x 204 x 107mm
AC 320 V
0.10 A
46
1.94 lbs / 0.88 kg
UL Listed, CE
outdoor
HEF160AAA
30 W
10L x 10H x 5W
254L x 254H x 136W
AC 115 V
0.25
60
3.73 lbs / 1.69 kg
UL Listed, CE
Outdoor
HEF160BAA
31 W
10L x 10H x 5W
254L x 254H x 136W
AC 115 V
0.13
60
8.8 lbs / 4.0 kg
UL Listed, CE
Outdoor
HEF500AAA
145 W
12L x 12H x 6W
323L x 323H x 155W
AC 115 V
1.3
70
8.77 lbs / 3.98 kg
UL Listed, CE
Outdoor
HEF500BAA
156 W
12L x 12H x 6W
323L x 323H x 155W
AC 230 V
0.7
70
8.77 lbs / 3.98 kg
UL Listed, CE
Outdoor
Part number
Cooling/heating Capacity
Dimensions (inch)
Dimensions (mm)
Rated Voltage (VDC)
Operating Current (A)
Noise (dB-A) @1.5M
Weight (lbs / kg)
Approvals
Indoor / Outdoor
Part number (Download spec sheets)
Impeller Diameter (mm)
Voltage (VAC)
Max. Speed (RPM)
Min. Speed (RPM)
Protection/ Option
Ingress Protection
Certification
10
115 VDC
--
--
--
IP54
--
230VAC
--
--
--
IP54
10
230VAC
--
--
--
IP54
10
230VAC
--
--
--
IP54
10
230VAC
--
--
--
IP54
10